For handler setup or hand test, a manual lid is often required as part of the test hardware set. We have refined our standard offerings so that with each socket you can receive a lid designed specifically for your application from one of five standard lid form factors: |
Clamshell Lids are used most in manual test applications. These lids provide an easy-to-use solution for repetitive cycling. Our innovative controlled travel design permits virtually effortless actuation and adjusts to accommodate a wide range of device thickness.< | |
The VCC or Vertical Compression Clamshell Lid is a clamshell lid without secondary actuation. Numerous customers prefer the convenience of pushing the device into the pocket with a single actuation. The VCC's unique design offers natural linear compression of the device.Our Clip-on Lid design has been given a new body to provide a more user friendly solution while offering the same quick turnaround, which is often a key requirement in handler setup hardware. |  |
| The Clip-on Lid design has been given a new body to provide a more user friendly solution while offering the same quick turn around, which is often a key requirement in handler setup hardware. |  |
|
One-Piece Bolt-On Lids are the most straightforward style of manual lid. When test times are long and price is the primary driver, this can be the optimal |  |
Integral Lid solutions are permanently attached to the socket and offer a more simplistic approach to low end test. In order to guarantee that the lid design meets your application requirements we offer a variety of options including:
- Multiple plunger configurations
- Thermal stream access holes
- Heat sinks
- Heat dissipating fans
- Spring loaded latches
|  |
|
 |
 |
|
 |
|
|
 |
|
 |